Godex GS220 Dokumentacja

Przeglądaj online lub pobierz Dokumentacja dla Czytniki kodów kreskowych Godex GS220. Godex GS220 bar code reader Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 82
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów

Podsumowanie treści

Strona 1 - Configuration Guide

Configuration Guide GS220

Strona 2 - Table of Contents

2–3 ³100215 Enable PARAF (Italian Pharmaceutical Codes) Support – Code 39 bar codes are converted to PARAF format. ³100205 * Disable PARAF Support

Strona 3 - Code Formatting

2–4 ³115413 Enable Alternate Code 39 Reference Comparison Check – assists with elements that are below the 2 to 1 (wide to narrow) element width req

Strona 4

2–5 ³100913 Alternative ITF first Bar Reference ³100903 * Normal ITF first Bar Reference ³100110 Enable Standard 2 of 5 ³100100 * Disable Standard

Strona 5

2–6 ³100316 Enable Hong Kong 2 of 5 ³100306 * Disable Hong Kong 2 of 5 ³115411 Enable Follett ITF ³115401 * Disable Follett ITF Codabar ³100114

Strona 6 - Introduction

2–7 ³100003 * Disable Code 11 ³108005 * Check for 1 Code 11 Check Digit ³108015 Check for 2 Code 11 Check Digits ³108004 * Do Not Check for 2 Cod

Strona 7 - Need To Start Over?

2–8 ³200734 Enable MSI Plessey MOD 10/10 Check Digit – Test MSI Plessey bar codes for a 2 digit Modulo 10 check digit. ³200724 * Enable MSI Plesse

Strona 8 - Code Types and Decode Rules

2–9 ³901800 ~ Minimum Symbol Length – Single-line default is 3. Combine this code with the proper code bytes (on page 12–1), to specify the mini

Strona 9 - Code 39

2–10 ³902200 ~ Code Length Lock #2 ³902300 ~ Code Type Lock #2 ³902400 ~ Code Length Lock #3 ³902500 ~ Code Type Lock #3 ³902600 ~ Code Length

Strona 10

3–1 Supplements ³101217 Enable Two Digit Supplements ³101207 * Disable Two Digit Supplements ³101212 * Enable Two Digit Redundancies – The scanner

Strona 11 - 2 OF 5 CODES

3–2 ³101417 Enable Bookland (978) Supplement Required ³101407 * Disable Bookland (978) Supplement Required ³101314 Enable 977 (2 Digit) Supplement

Strona 12

iTable of Contents Introduction Bar Code Configuration Methods... 1–1 Single-Code Meth

Strona 13 - Code 11

3–3 ³101000 * Enable 2 Digit Supplements with 37x, 43x, or UPC # System 5 ³101010 Disable 2 Digit Supplements with 37x, 43x, or UPC # System 5 ³101

Strona 14 - Plessey Codes

3–4 ³101214 Enable Code ID’s with Supplements ³101204 * Disable Code ID’s with Supplements ³118406 * Beep Once on Supplements ³118416 Beep Twice o

Strona 15 - Additional Decode Features

3–5 ³ 12501 7 No Supplement Checking if EAN-13 Code is just scanned ³ 12500 7 * Normal Supplement Checking

Strona 17

4–1 GS1 Databar GoDEX’s GS220 scanners with software #14810 and higher can be configured to scan GS1 Databar type bar codes. ³100011 Double Borde

Strona 18 - Supplements

4–2 GS1 Databar Limited ³100414 Enable GS1 Databar Limited ³100404 * Disable GS1 Databar Limited ³114903 * Transmit GS1 Databar Limited CD ³11491

Strona 19

5–1 ISBT Code 128 Implementation Configuration Mode ³138417 Enable ISBT Code 128 ³138407 Disable ISBT Code 128 The bar codes below enable or disable

Strona 20

5–2 Concatenation Configuration Mode The following bar codes are used to configure variable time requirements used to find the second bar code of the

Strona 21

5–3 ³438490 Donation Identification Number + Donor Identification Number =á + &; Concatenation ³4384100Donation Identification Number + Confid

Strona 22 - ³ 12500 7

5–4 The following example demonstrates how to configure the User-Defined ISBT identifiers: Assume the left-hand identifiers are the ISBT defined don

Strona 23

ii Scanner OperationConfiguration Mode Options...6–1Scan Buffers...

Strona 24 - GS1 Databar

66–1 Scanner Operation Configuration Mode Options ³118117 Allow Configuration Mode on Power Up – the scanner can only enter Configuration mode bef

Strona 25 - GS1 Databar Expanded

6–2 Redundant Scans ³301100 * 0 Redundant Scans – Requires 1 good decode for a good scan. ³301110 1 Redundant Scan – Requires 2 consecutive decodes

Strona 26 - ISBT Code 128 Implementation

6–3 LED Options ³ 11831 3 Flash Green LED if Rescan Allowed – This indicates same symbol timeout has elapsed. ³ 11830 3 Do Not Flash Green LED if R

Strona 27

6–4 Beeper Options ³318575 * Normal Tone ³318565 Optional Tone 1 ³318555 Optional Tone 2 ³318545 Optional Tone 3 ³318535 Optional Tone 4 ³318525 Op

Strona 28 - ³4384140

6–5 ³118417 Beep on BEL Command – The scanner beeps when it receives a BEL character from the host. If a number is sent within 200 msecs before the

Strona 29 - =&³ =G&a505d0

6–6 Data Transmission Delays Use these codes to select the amount of delay between sending data characters from the scanner to the host. This helps

Strona 30

6–7 Communication Time Out Options ³118412 Enable Communications Time Out ³118402 * Disable Communications Time Out ³118413 * Beep Before Transmi

Strona 31 - Redundant Scans

6–8 Host Scanner Commands ³118015 Enable D/E Disable Command – The scanner will disable scanning after it receives an ASCII “D” from the host devic

Strona 32 - LED Options

6–9 ³115916 Transmit Scanner ID byte with receipt of an “i” (69H) via RS232 – The ID byte is transmitted as 3 bytes (i.e. 0, 0, 1). ³115906 * Don’

Strona 33 - Beeper Options

6–10 ³141715 Use Protocol Prefix and Suffix for Bar Code Transmission ³141705 * No Protocol Prefix and Suffix for Bar Code Transmission ³119917 Ena

Strona 34

iii RS232Parity Features ... 9–1Baud Rate...

Strona 35 - Data Transmission Delays

777–1 Prefixes/Suffixes Scan the Enter Configuration Mode bar code before trying to set these features (see the Multi-Code Method on page 1–1). User

Strona 36

7–2 User Configurable ID Characters, Code Specific ³105507 * Use Configurable Code ID Bytes as Prefixes – User configured, code specific ID bytes a

Strona 37 - Host Scanner Commands

7–3 ‡ Enter configuration mode then scan this bar code followed by the three code byte bar codes (on page 12–1) that represent a unique ID charact

Strona 38

7–4 Standard Prefix Characters ³116615 Enable STX Prefix – The scanner will transmit a Start of TeXt (ASCII 02H) before each bar code. ³116605 * D

Strona 39 - Test Modes

7–5 ³107916 Enable SANYO ID Characters ³107906 * Disable SANYO ID Characters ³105512 Enable Manufacturer ID Prefix ³105502 * Disable Manufacturer

Strona 40

7–6 Standard Suffix Characters ³116613 * Enable CR Suffix – The scanner transmits a carriage return after each bar code. ³116603 Disable CR Suffi

Strona 41

7–7 Longitudinal Redundancy Check A Longitudinal Redundancy Check (LRC) is an error checking character that is calculated across a sequence of data

Strona 42

7–8 Character Replacements To replace a character: 1. Scan the enter/exit configuration mode bar code (on page 1–1). 2. Scan the character to replac

Strona 43 - Standard Prefix Characters

7–9 User Configurable Suffixes, All Data Note: Scan the Enter/Exit Configuration mode code before trying to set this feature. Refer to Multi-Code M

Strona 44

7–10 Special Formats ³107914 Enable SINEKO Mode ³107904 * Disable SINEKO Mode ³116711 Enable Newcode Formatting Mode A ³116701 * Disable Newcode

Strona 46 - Block Check Character

888–1 Code Formatting UPC/EAN Formatting ³107517 * Transmit UPC-A Check Digit ³107507 Do Not Transmit UPC-A Check Digit ³107516 Transmit UPC-E Chec

Strona 47 - Character Replacements

8–2 ³107513 Transmit Lead Zero on UPC-E – This option will transmit a zero before each UPC-E bar code. ³107503 Do Not Transmit Lead Zero on UPC-E ³

Strona 48

8–3 Codabar Formatting ³107717 Transmit Codabar Start/Stop Characters –Transmits Codabar’s Start/stop characters before and after each bar code. ³1

Strona 49 - Special Formats

8–4 Code 39 Formatting ³107715 Transmit Mod 43 Check Digit on Code 39 – This feature works in conjunction with Mod 43 Check Digit on Code 39 option,

Strona 50

8–5 Plessey ³107816 Transmit UK Plessey Check Digit – The scanner will transmit UK Plessey Check Digit characters and must be used with the UK Ples

Strona 52 - Codabar Formatting

999–1 RS232 ³415554 * Enable RS232 Mode – the scanner will work with RS232 +/-12V serial output. Parity Features A parity bit is an extra data bit

Strona 53 - Code 11 Formatting

9–2 ³415850 * 9600 BAUD Rate ³415840 4800 BAUD Rate ³415830 2400 BAUD Rate ³415820 1200 BAUD Rate ³415810 600 BAUD Rate ³415800 300 BAUD Rate Data/S

Strona 54 - 2 of 5 Code Formatting

9–3 ³115815 * Character RTS/CTS – Activates/Deactivates RTS signal for each character. ³115805 Message RTS/CTS – Activates RTS before sending the fi

Strona 55

9–4 ³115915 Enable RTS Counter Toggle – The scanner will toggle the RTS line on a good decode. ³115905 * Disable RTS Counter Toggle ³115914 Enable

Strona 56 - Baud Rate

1–1 IntroductionYour new scanner has been factory configured with a set of default parameters. Since many host systems have unique formats and protoc

Strona 57 - Hardware Handshaking

9–5 ³115814 Enable 5 NAK Retries Allow up to 5 retransmissions of the data if a NAK is received. ³115804 * Disable 5 NAK Retries ³125210 Enable G

Strona 59 - Software Handshaking

10–1 Keyboard Enable Keyboard Emulation ³999994 Load Keyboard Wedge Defaults – Loads the default settings for keyboard wedge mode. ³5155153Enable S

Strona 60 - Miscellaneous

10–2 ³416200 Belgium Keyboard ³4162100Japan Keyboard ³416270 IBM 4700 Financial Keyboard ³416290 Sweden/Finland Keyboard ³4162110 Slovenian Keyboard

Strona 61

10–3 ‘Dumb’ Terminal Selections Note: The following terminals may require custom cables. ³316400 IBM Terminal Keyboards ³316410 Reserved Terminal K

Strona 62 - Keyboard

10–4 Special Keyboard Features ³116311 Transmit Make Code Only – Not available on all models. ³116301 * Transmit Make/Break Code – Not available o

Strona 63 - Keyboard/System Type

10–5 ³116214 Enable Auto Detect Mode (AT/PS2) – Automatically detects caps lock status. ³116204 * Disable Auto Detect Mode (AT/PS2) ³116214 Enable

Strona 64 - ‘Dumb’ Terminal Selections

10–6 ³116302 Enable Right Alt Key Sequencing ³116312 Disable Right Alt Key Sequencing ³116413 Enable LaCaixa Special Keyboard Prefix & Suffix S

Strona 65 - Special Keyboard Features

10–7 Control Sets In general, standard bar code symbologies will only encode the ASCII character set. Function keys, arrow keys and many other exte

Strona 66

10–8 ASCII (HEX) ASCII Control Extended Key 00H Null Numeric Keypad + (Plus) 01H SOH Num Lock 02H STX Down Arrow 03H ETX Numeric Keypad - (M

Strona 67 - InterScan Code Delays

1–2 Need To Start Over? Scan the Recall Defaults bar code to erase all previous settings and return the scanner to its factory default communicatio

Strona 68 - Control Sets

11–1 USB ³4155114Enable USB Interface♦ ³999978 Enable Low Speed USB Defaults♦ ♦ This feature is limited to GoDEX scanners without integrated Lo

Strona 69

11–2 ³ 11781 7 Enable Bar Code ID ³ 11780 7 Disable Bar Code ID ³ 11981 7 Enable USB Reserve Code #1 ³ 11980 7 Disable USB Reserve Code #1 ³ 99997 3

Strona 70 - ³3164010

12–1 Code Bytes Usage The scanner must be in Configuration Mode for the features requiring code bytes for configuration. The Enter/Exit Configuratio

Strona 71

12–2 ³8 Code Byte 8 ³9 Code Byte 9 Reserved Codes ³999988 ~ Enable Reserved Code – Contact GoDEX for information about this feature. ³999987 ~ D

Strona 72 - Code Bytes Usage

12–3 ASCII Reference Table HEX Value Decimal Value/ Code Byte Value Character Control Keyboard Eqv 00 000 NUL @ 01 001 SOH A 02 002 STX B 03

Strona 73 - Code Type Table

12–4 HEX Value Decimal Value/ Code Byte Value Character Control Keyboard Eqv 1D 029 GS ^ 1E 030 RS _ 1F 031 US space,blank 20 032 SP 21 033

Strona 74 - ASCII Reference Table

12–5 HEX Value Decimal Value/ Code Byte Value Character Control Keyboard Eqv 3C 060 < less than 3D 061 = 3E 062 > greater than 3F 063

Strona 75

12–6 HEX Value Decimal Value/ Code Byte Value Character Control Keyboard Eqv 5A 090 Z 5B 091 [ shift K 5C 092 \ shift L 5D 093 ] shift M 5E

Strona 76

12–7 HEX Value Decimal Value/ Code Byte Value Character Control Keyboard Eqv 79 121 y 7A 122 z 7B 123 { 7C 124 | vertical slash 7D 125

Strona 77

12–8 Key At Scan Code PS2 Scan Code 3151 Prefix/Suffix Value Hex = Decimal F8 0AH 42H 3FH 97H = 151 F9 01H 43H 47H 98H = 152 F10 09H 44H

Strona 78

2–1 Code Types and Decode Rules Bar code descriptions marked with an asterisk ( * ) define a feature that is a factory default. Bar codes marked with

Strona 79

13–1 Miscellaneous Features Custom Defaults ³ 84660 0 Enable Factory Defaults – Scan this code followed by Recall Defaults code to enable and load fa

Strona 80 - Miscellaneous Features

13–2 Serial Program ModeFor Serial Program Mode, all commands must be framed by an STX (02 Hex) and ETX (03 Hex). To recall defaults: 1. Transmit &l

Strona 81 - Serial Program Mode

14–1 Contact Information 14www.godexintl.comGodex [email protected]+886-2-2225-8580Godex [email protected]+86-21-5665-1313Go

Strona 82 - Contact Information

2–2 Code 128 ³100113 * Enable Code 128 ³100103 Disable Code 128 ³100314 Enable UCC/EAN-128 ‘]C1’ Code Formatting –For Coupon Code 128, see page 3–

Komentarze do niniejszej Instrukcji

Brak uwag